SPL Meter 0.4.1: name a dead input, and stop the spectrogram smearing its labels #16

Merged
michael merged 2 commits from claude/spl-silent-input into main 2026-09-23 10:03:28 -04:00
2 Commits
Author SHA1 Message Date
Waters ChurchandClaude Opus 5 c8b51c6c2f Spectrogram: stop dragging the labels along with the picture
The spectrogram scrolled by copying the visible canvas onto itself one step
along. That canvas already held the frequency labels and gridlines, because
they were drawn straight onto it, so every frame smeared them sideways and
left a trail. Arrived with the labels in 0.3.0; the gridlines did it too.

Only measured pixels belong on a surface that scrolls. The history now lives
on its own offscreen canvas that holds nothing but spectrum, and the visible
canvas is repainted from scratch each frame — history first, annotations
over the top. Nothing drawn as an annotation can reach the scroll buffer by
construction, rather than by remembering to clear the right strip.

The layout was muddled in the same place and is fixed with it: the gutter
used to be reserved along the bottom while the labels were drawn down the
left, overlapping the plot. Labels now sit beside the axis they describe —
down the left when frequency runs vertically, with room for "12.5k", and
along the bottom when it runs horizontally.

Verified both orientations by fingerprinting the gutter and the plot two and
a half seconds apart: gutter identical, plot changed.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-23 09:58:32 -04:00
Waters ChurchandClaude Opus 5 c464e5b4ca SPL Meter 0.4.0: a dead input must not look like a quiet room
AB's meter appeared to halt for a day and a half. Nothing had halted: the
capture child had run continuously since the machine was restarted, never
stalled, never exited, and was delivering twenty frames a second. Every one
of them was digital silence, because Dante Via stopped passing audio after
the reboot — the Timers module's LTC listener, on channel 16 of the same
device, had been reporting no signal for exactly as long.

The module's part in that was reporting "ok" through all of it and drawing
a steady -83, which is the -200 floor plus the +117 calibration offset. A
plausible number on a wall is believed, and a green dot beside it says the
number is worth believing. That is worse than showing nothing.

So silence is now a state the module names. Below -150 dBFS unweighted the
input is not quiet, it is absent: a microphone in a silent room still reads
about -83, and even a muted converter dithers. Five seconds of that on every
channel and health() goes to error naming the device and how long it has
been dead, the tiles stop drawing a level and say "No audio" with how long,
and the status dot goes red.

Verified both directions, which is the half that matters: BlackHole with
nothing routed into it is caught in five seconds, and a real microphone in a
quiet room at -49 dBFS is never flagged.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-23 09:54:27 -04:00