Files
ProdDash/modules/spl-meter/module.json
Waters ChurchandClaude Opus 5 87929bfd0b Don't take the server down when the module unmounts
Deploying 0.3.0 to AB crashed the ProdDash server on restart:

  TypeError: Cannot read properties of null (reading 'streams')
      at server.js:273  req.on('close', () => state.streams.delete(res))

teardown() nulls `state` and then ends every open stream, which fires each
request's close handler — and the handler reached back through the `state`
it had just discarded. Any re-init with a browser connected would do it, so
saving admin config while a dashboard was open was enough to stop the whole
server, every module with it.

The stream handler now closes over this mount's Set rather than the module's
state: after teardown it deletes from a set nobody reads, which is harmless.
The same hazard existed anywhere a callback could outlive the mount — the
keepalive ping, a frame arriving from the listener mid-teardown, and the
/measure interval — and each is closed over or guarded now.

Reproduced first (open an SSE client, save config, watch it fall over) and
confirmed fixed against the same sequence.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-17 16:06:47 -04:00

95 lines
2.6 KiB
JSON

{
"id": "spl-meter",
"name": "SPL Meter",
"version": "0.3.1",
"proddash": ">=1.5.0",
"description": "Calibrated sound level, Leq and RTA from an audio input on this machine",
"permissions": [
{
"kind": "microphone",
"reason": "Measuring sound level from an audio input on this machine"
}
],
"client": "client.js",
"server": "server.js",
"style": "style.css",
"minSize": {
"w": 2,
"h": 1
},
"defaultSize": {
"w": 3,
"h": 2
},
"configGroups": {
"Input": {
"toggle": "enabled"
},
"Measurement": {
"columns": 2
},
"Calibration": {
"collapsed": "whenSet",
"help": "A sound level calibrator fits over the microphone capsule and emits a known level, almost always 94 dB at 1 kHz. Put it on, press Measure beside the channel, and copy the offset it reports into the box. Without this the meter still works, but it reads in dB relative to full scale and every tile says so."
}
},
"configSchema": {
"enabled": {
"type": "switch",
"label": "Sound level measurement",
"group": "Input",
"default": false
},
"device": {
"type": "select",
"label": "Audio device",
"group": "Input",
"showWhen": "enabled",
"default": "",
"optionsRoute": "/devices"
},
"channels": {
"type": "string",
"label": "Channels on that device (1-based, comma separated)",
"group": "Input",
"showWhen": "enabled",
"default": "1",
"help": "One meter per channel — \"1\" for a single measurement mic, \"1,2\" for a stereo pair."
},
"weighting": {
"type": "select",
"label": "Weighting",
"group": "Measurement",
"default": "A",
"options": [
{
"value": "A",
"label": "A — how loud it sounds"
},
{
"value": "C",
"label": "C — keeps the low end"
},
{
"value": "Z",
"label": "Z — no weighting at all"
}
]
},
"bands": {
"type": "switch",
"label": "Spectrum analysis",
"group": "Measurement",
"default": true,
"help": "1/48-octave bands for the RTA and spectrogram tiles, which each fold them to their own banding. Turn it off if you only ever show the number."
},
"calibration": {
"type": "string",
"label": "Offsets in dB, one per channel",
"group": "Calibration",
"default": "",
"help": "Leave empty and every reading is dB relative to full scale, labelled dBFS so nobody mistakes it for real SPL."
}
}
}