ProPresenter 21.4 exposes no timecode through any API, so read the LTC
where it actually lives — the audio feed:
- tools/ltc-reader.js: zero-dependency SMPTE LTC decoder (biphase-mark,
adaptive bit clock, envelope-scaled comparator) fed s16le PCM on stdin
from ffmpeg/sox; POSTs running/stopped/nosignal + timecode + frame rate
(incl. 29.97 drop-frame) to the module. --selftest runs an encoder→
decoder suite (24/25/30 fps, DF minute counting, low level + noise + DC,
dropout recovery); --demo synthesizes live LTC through the real decoder
and ingest path with no audio hardware.
- Module: POST /ltc ingest route (optional bearer token, validated body,
6 s staleness with automatic fallback to the API probe / stage source),
richer LTC state (status, fps, df, reader source), health messages.
- Client: LTC card shows Running · <rate> / Stopped (held frame) /
No signal; works LTC-only with no ProPresenter host configured; the
reader-fed card no longer grays out when only ProPresenter is down.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
ProPresenter's HTTP API has no timecode route (verified: 21.4 returns
404), but its classic stage-display websocket still answers — so LTC now
comes from a stage layout field labeled "LTC": a zero-dependency RFC6455
client (stage-ws.js) authenticates (new stagePassword admin config),
resolves the LTC-labeled frame's uid from the layout list, and treats any
message carrying that uid as the timecode text. "Receiving" is a 2.5s
staleness heuristic; frozen or placeholder text reads as no-signal. The
HTTP probe stays authoritative when it ever answers (a 404 verdict is
retried once a minute), and the LTC card surfaces the reason when
timecode is unavailable (bad stage password, no LTC field). pp-timers-mock
grows a /stagedisplay websocket with --stage-pwd and --no-ltc-field to
exercise every path.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
New configSchema type 'endpoint' declared in the module spec: anything
that points at a device or service on the network must be one endpoint
field, rendered identically for every module in /admin as a joined
Host/IP : Port control and stored/handed to the module server as
{ host, port }. Migrates all three connection modules — ProdCom (was a
full URL field), ProPresenter and Timers (were separate host + port
fields). Legacy stored configs (prodcomUrl / flat host+port) keep
working until the admin form is re-saved, at which point the new shape
replaces them. MODULE-GUIDE documents the type and the presentation
rule: no split host/port fields, and full URLs only for genuine web
addresses.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01RNYUv9EyrGSFmCnmH7WYKH
New propresenter-timers module: polls /v1/timers + /v1/timers/current
(shapes verified against openapi.propresenter.com), probes the
undocumented /v1/timecode/status for LTC and honestly reports
"not available on this ProPresenter" when absent. Per-tile timer/LTC
selection via a Timers ▾ header menu (never-seen timers default on),
responsive auto-sized cards with state-derived colors (the API exposes
no per-timer color), unmistakable overrun. Includes tools/pp-timers-mock.js
for developing without a real ProPresenter.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>