Commit Graph
2 Commits
Author SHA1 Message Date
Waters ChurchandClaude Opus 4.8 1d46657e06 Timers: LTC is listener-only; admin switch, device/channel, grouped settings
Simplify LTC to its one working source — the built-in audio listener — and
make the admin UI reflect it.

Module:
- Remove the stage-display websocket source (stage-ws.js, stagePassword)
  and the /v1/timecode/status API probe — both dead on ProPresenter 21.4.
- Remove the remote-reader ingest (POST /ltc, ingestToken, tools/
  ltc-reader.js): the module owns LTC end to end now. The decoder selftest
  moves to modules/propresenter-timers/ltc.selftest.js so the engine stays
  covered.
- composeLtc collapses to the listener: running/stopped/nosignal, or a
  clear note when disabled / no device / capture failed / starting.
- Manifest: ltcEnabled is now a `switch`; ltcDevice and ltcChannel carry
  showWhen:"ltcEnabled"; ProPresenter and LTC fields carry `group` labels.

Shell (admin) — backward-compatible additions, coordinate with the shell lane:
- New `switch` field type (boolean shown as the enable-toggle control).
- `group`: consecutive fields render under a labeled subsection.
- `showWhen: "<key>"`: a field is shown only while that boolean/switch is
  on (and actually collapses — .field[hidden] override, since .field's
  display:flex outranks the [hidden] UA default).
- applyConfigPatch coerces `switch` as boolean. Documented in MODULE-GUIDE.

Verified: engine selftest (29 checks); listener decodes BlackHole loopback
(running 30fps, ageMs); device picker lists inputs; POST /ltc now 404s;
admin shows two labeled groups, the switch, and device/channel appearing
only when the switch is on (computed display none↔flex confirmed).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-09-10 13:29:06 -04:00
Waters ChurchandClaude Fable 5 b95aa7dc34 Timers: built-in LTC listener, configured in the admin page
The LTC listener now lives inside the module: it spawns the native
ltc-capture helper (moved into the module folder, compiled on first use,
exact-name device matching) for the admin-selected input device, extracts
the configured channel, and decodes SMPTE LTC in-process (ltc.js — the
engine, shared with tools/ltc-reader.js, which remains the remote-machine
option posting to /ltc).

Admin config: an "LTC listener" switch, an audio-device select populated
live from the new GET /ltc/devices route, and a 1-based channel number.
The switch off means LTC is gone entirely: no LTC entry in the Add-tile
picker, no LTC row in the Timers menu or All-timers grid, no stage/API
probes, and POST /ltc answers 409. Source precedence with it on:
listener-with-data, fresh remote reader, listener's own no-signal verdict,
then the legacy API/stage chain.

Shell (admin page): `select` fields learn `optionsRoute` — options fetched
from a module route at render, saved value kept selectable when the route
or device is gone. Documented in MODULE-GUIDE; backward compatible.
Coordinate with the shell lane before its next admin.js change.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-09-08 17:21:48 -04:00