Name matrix inputs, fix the meter scale, add output meters
Found on the live S31 (read-only, plus meter subscriptions):
- Matrix inputs are named at /Matrix_Inputs/N/Channel_Input/name (an
address missing from DiGiCo's 2014 list). Their names now appear in
every matrix-send dropdown, preset and the new matrix_in_N_name
variables, falling back to "Matrix In N" when empty. Matrix inputs also
get trim and phase.
- Console names are space-padded where the surface wraps them; every name
is now trimmed and its whitespace runs collapsed ("LEAD V RESI").
- Meter values are inverted: 127 is silence and lower is louder, about
1 dB per step below full scale (silent channels read 127, the room mic
36-48). The module treated 127 as peak. Level meters now read dBFS
(approximate), gauges span -60..0 dBFS, signal and peak thresholds are
in dBFS; gain reduction reads dB of reduction, 127 meaning none.
- Bus and matrix outputs have meters (/Aux_Outputs, /Group_Outputs and
/Matrix_Outputs/N/Output/meter): new signal, peak, value and gauge
feedbacks and "Buss meters" / "Matrix meters" presets.
3002 presets, 2.7 MB. npm test: 425 checks pass on Node 25 and on
Companion's Node 22. Deployed and checked on the booth Companion 5.1.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
+44
-23
@@ -6,7 +6,7 @@ This connection does two things:
|
||||
matrix outputs, control groups, graphic EQs, snapshots) and builds its dropdowns, variables and
|
||||
presets from the live names. Faders, mutes, solos, pans, aux sends, group assigns, matrix sends,
|
||||
control groups, graphic EQs, per-channel switches (phantom, EQ in, filters, inserts ...) and
|
||||
snapshots are covered, with feedbacks, variables, rotary-encoder presets and input meters.
|
||||
snapshots are covered, with feedbacks, variables, rotary-encoder presets and input and output meters.
|
||||
2. **Relays the DiGiCo iPad app.** An S-Series console talks to exactly one iPad at a time. Companion
|
||||
takes that slot and the iPad apps connect to this computer instead; everything an app sends is
|
||||
forwarded to the console unchanged, and everything the console sends is copied to every app, so
|
||||
@@ -60,10 +60,13 @@ and anything they change reaches this module too, so feedbacks follow moves made
|
||||
|
||||
On every connect (and on the **Reload** action, and automatically after the console was silent for
|
||||
20 seconds and comes back) the module asks for the console name, the matrix, control group and graphic EQ
|
||||
counts, the buss types and modes, every name, the session name, the snapshot list, and the fader, mute,
|
||||
counts, the buss types and modes, every name (inputs, busses, matrix inputs and outputs, control groups, graphic EQs), the session name, the snapshot list, and the fader, mute,
|
||||
solo and pan of everything that answered. The console does not answer the input and buss counts, so an
|
||||
entity exists when its **name** answered; entities that never answer are hidden from dropdowns, variables
|
||||
and presets. Dropdown entries read `1 · KICK In`, `24 · Monitors (group)`, `3 · Message · cue 4`.
|
||||
and presets. Dropdown entries read `1 · KICK In`, `24 · Monitors (group)`, `3 · Message · cue 4`. The console pads names
|
||||
with trailing spaces and wraps long ones with runs of spaces; every name is trimmed and its whitespace collapsed to single
|
||||
spaces when it arrives, so dropdowns, variables and presets show `Studio TB`, not `Studio TB `. A matrix input with
|
||||
no name reads `Matrix In N`.
|
||||
When a name, a buss mode or the snapshot list changes, the definitions are rebuilt a moment later.
|
||||
Sends, group assigns, matrix sends, graphic EQ gains and the per-channel switches are **not** bulk-loaded:
|
||||
each is read the first time a button or action needs it.
|
||||
@@ -89,7 +92,7 @@ is not known yet.
|
||||
| Matrix | output mute, fader set/adjust; matrix send on/off, level set/adjust |
|
||||
| Control groups | mute, solo, fader set/adjust |
|
||||
| Graphic EQ | in/out, band gain set/adjust (bands 1-32) |
|
||||
| Channel strip | per input and per buss: phantom, phase, pad, EQ in, compressor in, gate in, high-pass in, low-pass in, delay in, insert A/B in (on/off); trim (-40 to +40 dB), analog gain (0 to 60 dB), filter frequencies (20 to 20000 Hz) (set/adjust; trim also on matrix outputs) |
|
||||
| Channel strip | per input and per buss: phantom, phase, pad, EQ in, compressor in, gate in, high-pass in, low-pass in, delay in, insert A/B in (on/off); trim (-40 to +40 dB), analog gain (0 to 60 dB), filter frequencies (20 to 20000 Hz) (set/adjust; trim also on matrix outputs and matrix inputs, phase also on matrix inputs) |
|
||||
| Snapshots | fire (pick from the list or type an index), next, previous |
|
||||
| Console | reload, raw OSC, relay: forget all iPads |
|
||||
|
||||
@@ -116,12 +119,12 @@ own value changes.
|
||||
* Boolean (button colour): input muted / solo; aux send on; group assigned; buss muted / solo; matrix output muted /
|
||||
solo; control group muted / solo; **matrix send on**; **graphic EQ in**; snapshot is current; fader level above/below
|
||||
a threshold; aux send level above/below; console link alive; relay has an iPad; every channel-strip switch
|
||||
(phantom, phase, pad, EQ in, compressor in, gate in, high-pass in, low-pass in, delay in, insert A/B in); and the meter
|
||||
feedbacks below.
|
||||
(phantom, phase, pad, EQ in, compressor in, gate in, high-pass in, low-pass in, delay in, insert A/B in; phase also
|
||||
per matrix input); and the meter feedbacks (signal present, peak hold) for inputs, busses and matrix outputs.
|
||||
* Value (put live numbers in button text with a preset's local variable): input fader and pan; aux send level, On/Off
|
||||
and pan; buss / matrix / control group fader; **matrix send level**; **graphic EQ band gain**; trim, analog gain and
|
||||
filter frequency per input and buss (trim also per matrix output); current snapshot name; input meter value. Levels
|
||||
read `-inf` at or below -90 dB.
|
||||
filter frequency per input and buss (trim also per matrix output and matrix input); current snapshot name; meter level
|
||||
text (see **Meters**). Levels read `-inf` at or below -90 dB.
|
||||
* Numeric, for gauges (see **Gauges** below): the `*_pos` position feedbacks, `input_pan_num` / `send_pan_num` and
|
||||
`geq_band_db`.
|
||||
* Advanced image bars (**legacy image**, deprecated by Companion 5.1, kept so existing buttons keep working): input
|
||||
@@ -142,7 +145,7 @@ number you feed to a gauge through a button local variable:
|
||||
| `input_fader_pos`, `buss_fader_pos`, `matrix_fader_pos`, `cg_fader_pos`, `send_level_pos`, `matrix_send_level_pos` | 0-100 | fader / send position on a fader taper; unknown reads 0 |
|
||||
| `input_pan_num`, `send_pan_num` | 0-1 | the console's pan, 0.5 = centre (unknown reads 0.5) |
|
||||
| `geq_band_db` | -12 to +12 | graphic EQ band gain in dB (unknown reads 0) |
|
||||
| `input_meter_pos` | 0-100 | input meter (0-127 scaled); has the *Meter* option level / gate / compressor reduction |
|
||||
| `input_meter_pos`, `buss_meter_pos`, `matrix_meter_pos` | 0-100 | meter position: levels over -60..0 dBFS (-inf = 0), gain reduction over 0..20 dB; the input meter has the *Meter* option level / gate / compressor reduction |
|
||||
|
||||
The fader taper maps +10 dB = 100, +5 = 87.5, 0 = 75, -5 = 65, -10 = 55, -20 = 40, -30 = 28, -40 = 18, -50 = 11 and
|
||||
-60 = 6 (straight lines in between), falls to about 1 just above -90 dB, and reads 0 at or below -90 dB (off).
|
||||
@@ -158,7 +161,7 @@ To add a gauge to your own button in Companion 5.1:
|
||||
|
||||
## Variables
|
||||
|
||||
`input_N_name|fader|mute|pan`, `buss_N_name|mode|stereo|fader|mute`, `matrix_N_name|fader|mute`,
|
||||
`input_N_name|fader|mute|pan`, `buss_N_name|mode|stereo|fader|mute`, `matrix_N_name|fader|mute`, `matrix_in_N_name`,
|
||||
`cg_N_name|fader|mute` (only for entities that exist), `snapshot_index|name|cue|count`, `console_name`,
|
||||
`session_name`, `connected`, `relay_clients`, `relay_client_ips` and `last_change`. Use them as
|
||||
`$(label:input_1_name)` with the connection's label. There are no per-send variables: use the value feedbacks.
|
||||
@@ -178,25 +181,42 @@ buttons.
|
||||
| Sends to *aux name* | One section per named aux buss: per input an **On/off** button (green when on, shows the level) and a **Level (knob)** (turn = send level, press = on/off, with a gauge) |
|
||||
| Group *group name* | One section per named group buss: per input an **Assign** toggle, green when assigned |
|
||||
| Matrix, Control groups | Mute and fader knob (with a gauge) per output / group |
|
||||
| Matrix sends to *output name* | One section per matrix output: per matrix input an **On/off** button (green when on; shows `Matrix In N` and the level) and a **Level (knob)** (turn = send level, press = on/off, with a gauge) |
|
||||
| Matrix sends to *output name* | One section per matrix output: per matrix input an **On/off** button (green when on; shows the matrix input's name and the level) and a **Level (knob)** (turn = send level, press = on/off, with a gauge) |
|
||||
| Graphic EQs | One **In/out** toggle per graphic EQ, green when in |
|
||||
| Snapshots | **Fire** per snapshot (green when current), next, previous, current (display) |
|
||||
| Input meters | Level, gate gain reduction and compressor gain reduction buttons per input, each with a vertical gauge at the right edge (green below 70, amber 70-90, red above 90) |
|
||||
| Buss meters, Matrix meters | One level meter button per named buss and per matrix output, same vertical gauge |
|
||||
| Console | Reload, connection status, relay status |
|
||||
|
||||
Busses and control groups with no name are unused slots and get no presets. If the preset list would exceed
|
||||
3000 entries or 4 MB, the per-input gate / compressor reduction meter presets are left out first, then the
|
||||
3200 entries or 4 MB, the per-input gate / compressor reduction meter presets are left out first, then the
|
||||
per-input aux send level knobs, and a warning is logged.
|
||||
|
||||
## Meters
|
||||
|
||||
Input meters are subscribed on the console the first time a meter feedback renders (ids start at 5000 so
|
||||
they never collide with an iPad's). The console then streams values 0-127 several times a second; the
|
||||
module re-checks the meter feedbacks at most 10 times a second. Level is the post-fader input meter; gate and
|
||||
compressor gain reduction are the two reduction meters. There is no known buss meter address, so busses
|
||||
have no meters. The console keeps one subscription table: an iPad connecting clears it (`/Meters/clear`),
|
||||
and the module re-subscribes half a second after it sees that pass through the relay. Two iPads watching
|
||||
different banks both receive the mixed stream. The module never sends `/Meters/clear` itself.
|
||||
Meters are subscribed on the console the first time a meter feedback renders (ids start at 5000, so they never collide
|
||||
with an iPad's: input meters 5000-5260, buss meters 5400 + N, matrix output meters 5450 + N). The console then streams
|
||||
integer values 0-127 several times a second, only for the ones that changed, and the module re-checks the meter
|
||||
feedbacks at most 10 times a second, and only the buttons showing the meter that moved.
|
||||
|
||||
**The scale is inverted and approximate.** A level meter value is about the **dB below full scale**: 0 = full scale,
|
||||
42 = about -42 dBFS, **127 = silence (-inf)**. A gain reduction meter value is about the **dB of reduction** (0-12 is
|
||||
typical, 127 = inactive). It has not been calibrated against a reference tone, so treat the numbers as roughly 1 dB per
|
||||
step, not as a measurement.
|
||||
|
||||
| Feedback | What it shows |
|
||||
| --- | --- |
|
||||
| `input_meter_value`, `buss_meter_value`, `matrix_meter_value` | text: `-42` or `-inf` (dBFS, approx.); gain reduction meters: `3` (dB) |
|
||||
| `input_meter_pos`, `buss_meter_pos`, `matrix_meter_pos` | gauge position 0-100: levels over -60..0 dBFS, gain reduction over 0..20 dB |
|
||||
| `input_signal`, `buss_signal`, `matrix_signal` | signal present: level above a dBFS threshold (option, default -50; gain reduction meters: any reduction) |
|
||||
| `input_peak`, `buss_peak`, `matrix_peak` | level at or above a dBFS value (option, default -1) held for the *Hold* time; not for gain reduction meters |
|
||||
|
||||
Input meters are level (post-fader), gate gain reduction and compressor gain reduction. Output meters exist for aux
|
||||
busses, group busses (the address follows the buss's current aux / group side) and matrix outputs; they are level meters.
|
||||
Control groups and matrix inputs have no meter. The console keeps one subscription table: an iPad connecting clears it
|
||||
(`/Meters/clear`), and the module re-subscribes half a second after it sees that pass through the relay (and after a
|
||||
reconnect). Two iPads watching different banks both receive the mixed stream. The module never sends `/Meters/clear`
|
||||
itself.
|
||||
|
||||
## Troubleshooting
|
||||
|
||||
@@ -224,17 +244,18 @@ Levels, sends and pans are floats too. Numbers are 1-based, snapshot indexes 0-b
|
||||
| `/Console/Aux_Outputs/types` | 25 x i | 1 = aux, 0 = group |
|
||||
| `/Console/{Aux_Outputs,Group_Outputs,Input_Channels}/modes` | i per buss / input | 2 = stereo, 1 = mono |
|
||||
| `/Console/Session/Filename` | s | |
|
||||
| `/Input_Channels/N/Channel_Input/name`, `/Aux_Outputs/N/Buss_Trim/name`, `/Group_Outputs/N/Buss_Trim/name`, `/Matrix_Outputs/N/Buss_Trim/name`, `/Control_Groups/N/name`, `/Graphic_EQ/N/name` | s | matrix inputs have no name address |
|
||||
| `/Input_Channels/N/Channel_Input/name`, `/Matrix_Inputs/N/Channel_Input/name`, `/Aux_Outputs/N/Buss_Trim/name`, `/Group_Outputs/N/Buss_Trim/name`, `/Matrix_Outputs/N/Buss_Trim/name`, `/Control_Groups/N/name`, `/Graphic_EQ/N/name` | s | names arrive padded; the module cleans them |
|
||||
| `/{Input_Channels,Aux_Outputs,Group_Outputs,Matrix_Outputs,Control_Groups}/N/{fader,mute,solo}` | f | fader in dB, -150 = -inf |
|
||||
| `/Input_Channels/N/Panner/pan` | f | 0..1, 0.5 = centre |
|
||||
| `/Input_Channels/N/Aux_Send/M/{send_level,send_on,send_pan}` | f | |
|
||||
| `/Input_Channels/N/Group_Send/M/group` | f | |
|
||||
| `/Matrix_Inputs/N/Matrix_Send/M/{send_level,send_on}` | f | |
|
||||
| `/Matrix_Inputs/N/Matrix_Send/M/{send_level,send_on}` | f | a matrix send floors at -90 dB |
|
||||
| `/Matrix_Inputs/N/Channel_Input/{trim,phase}` | f | |
|
||||
| `/Graphic_EQ/N/{geq_in,geq_gain_1..32}` | f | |
|
||||
| `/Input_Channels/N/{Channel_Input,Filters,Channel_Delay,EQ,Dynamics,Insert}/...` and the buss equivalents | f | the channel-strip switches and values above |
|
||||
| `/Snapshots/Current_Snapshot`, `/Snapshots/count` | i | |
|
||||
| `/Snapshots/names` | one `/Snapshots/name` `iiis` per snapshot: index, cue x 100, ?, name | |
|
||||
| `/Snapshots/Fire_Snapshot_number`, `/Snapshots/Fire_Next_Snapshot`, `/Snapshots/Fire_Prev_Snapshot` | none | write-only int |
|
||||
| `/Input_Channels/N/Channel_Input/post_meter`, `/Input_Channels/N/Dynamics/GR_meter` | none | send `,ii [id, kind]` (kind 1 level and gate, 4 compressor) to subscribe |
|
||||
| `/Meters/values` | `ii...` | pushed pairs `[id, value]`, value 0..127 |
|
||||
| `/Input_Channels/N/Channel_Input/post_meter`, `/Input_Channels/N/Dynamics/GR_meter`, `/{Aux_Outputs,Group_Outputs,Matrix_Outputs}/N/Output/meter` | none | send `,ii [id, kind]` (kind 1 level and gate and outputs, 4 compressor) to subscribe |
|
||||
| `/Meters/values` | `ii...` | pushed pairs `[id, value]`, value 0..127: inverted scale, 127 = silence / inactive |
|
||||
| `/Meters/clear` | none | clears every subscription on the console; sent by iPad apps, never by this module |
|
||||
|
||||
Reference in New Issue