An iPad that stays quiet for *Forget an iPad after* seconds (0 = never) is dropped from the fan-out list, and at most
16 are kept. `$(label:relay_clients)` shows how many are live. Changing only the idle timeout, the iPad receive port or
Debug logging does not interrupt the relay or the console link; changing the relay port reopens the relay and keeps the
list of iPads. If the relay port is already in use the connection shows the warning "iPad relay: port N in use" and tries
again every 10 seconds (a console-link port that cannot be bound shows a connection failure and is retried the same way). Other controllers share the console through the relay,
and anything they change reaches this module too, so feedbacks follow moves made on the surface or on an iPad.
| Console receive port | 8000 | UDP port the module sends to |
| Local receive port | 9000 | UDP port the module listens on (the console's Send port) |
| Enable iPad relay | on | Turns the relay on |
| Relay port | 8000 | Where iPad apps send |
| iPad receive port | 9000 | Where relayed console traffic goes (0 = the app's own source port) |
| Forget an iPad after | 3600 s | Idle time before an iPad is dropped (0 = never; an iPad that only watches sends nothing). At most 16 iPads are kept; the least recently seen is dropped first |
| Debug logging | off | Logs every new address pattern once and all traffic at debug level |
counts, the buss types and modes, every name (inputs, busses, matrix inputs and outputs, control groups, graphic EQs), the session name, the snapshot list, and the fader, mute,
| Channel strip | per input and per buss: phantom, phase, pad, EQ in, compressor in, gate in, high-pass in, low-pass in, delay in, insert A/B in (on/off); trim (-40 to +40 dB), analog gain (0 to 60 dB), filter frequencies (20 to 20000 Hz) (set/adjust; trim also on matrix outputs and matrix inputs, phase also on matrix inputs) |
| `input_meter_pos`, `buss_meter_pos`, `matrix_meter_pos` | 0-100 | meter position: levels over -60..0 dBFS (-inf = 0), gain reduction over 0..20 dB; the input meter has the *Meter* option level / gate / compressor reduction |
| Sends to *aux name* | One section per named aux buss: per input an **On/off** button (green when on, shows the level) and a **Level (knob)** (turn = send level, press = on/off, with a gauge) |
| Matrix sends to *output name* | One section per matrix output: per matrix input an **On/off** button (green when on; shows the matrix input's name and the level) and a **Level (knob)** (turn = send level, press = on/off, with a gauge) |
| Input meters | Level, gate gain reduction and compressor gain reduction buttons per input, each with a vertical gauge at the right edge (green below 70, amber 70-90, red above 90) |
Meters are subscribed on the console the first time a meter feedback renders (ids start at 5000, so they never collide
with an iPad's: input meters 5000-5260, buss meters 5400 + N, matrix output meters 5450 + N). The console then streams
integer values 0-127 several times a second, only for the ones that changed, and the module re-checks the meter
feedbacks at most 10 times a second, and only the buttons showing the meter that moved.
**The scale is inverted and approximate.** A level meter value is about the **dB below full scale**: 0 = full scale,
42 = about -42 dBFS, **127 = silence (-inf)**. A gain reduction meter value is about the **dB of reduction** (0-12 is
typical, 127 = inactive). It has not been calibrated against a reference tone, so treat the numbers as roughly 1 dB per
step, not as a measurement.
| Feedback | What it shows |
| --- | --- |
| `input_meter_value`, `buss_meter_value`, `matrix_meter_value` | text: `-42` or `-inf` (dBFS, approx.); gain reduction meters: `3` (dB) |
| `input_meter_pos`, `buss_meter_pos`, `matrix_meter_pos` | gauge position 0-100: levels over -60..0 dBFS, gain reduction over 0..20 dB |
| `input_signal`, `buss_signal`, `matrix_signal` | signal present: level above a dBFS threshold (option, default -50; gain reduction meters: any reduction) |
| `input_peak`, `buss_peak`, `matrix_peak` | level at or above a dBFS value (option, default -1) held for the *Hold* time; not for gain reduction meters |
Input meters are level (post-fader), gate gain reduction and compressor gain reduction. Output meters exist for aux
busses, group busses (the address follows the buss's current aux / group side) and matrix outputs; they are level meters.
Control groups and matrix inputs have no meter. The console keeps one subscription table: an iPad connecting clears it
(`/Meters/clear`), and the module re-subscribes half a second after it sees that pass through the relay (and after a
reconnect). Two iPads watching different banks both receive the mixed stream. The module never sends `/Meters/clear`
| `/Input_Channels/N/{Channel_Input,Filters,Channel_Delay,EQ,Dynamics,Insert}/...` and the buss equivalents | f | the channel-strip switches and values above |
| `/Snapshots/Current_Snapshot`, `/Snapshots/count` | i | |
| `/Snapshots/names` | one `/Snapshots/name``iiis` per snapshot: index, cue x 100, ?, name | |
| `/Snapshots/Fire_Snapshot_number`, `/Snapshots/Fire_Next_Snapshot`, `/Snapshots/Fire_Prev_Snapshot` | none | write-only int |