christianandClaude Opus 5.5 46fb55533b Clear a fault once its check stops reporting it
Found in today's power-off test: a Shure/PSM check reports "conn" while its
connection is down and per-channel results once it is back, so the
"AXIENT 1 OFFLINE" tracker never saw OK. The button looked green, but no
CLEAR was logged and a hold on RF would still have restarted the Shure
connections. A tracker missing from a round now gets an OK update.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>