Found in today's power-off test: a Shure/PSM check reports "conn" while its connection is down and per-channel results once it is back, so the "AXIENT 1 OFFLINE" tracker never saw OK. The button looked green, but no CLEAR was logged and a hold on RF would still have restarted the Shure connections. A tracker missing from a round now gets an OK update. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>