ATEM: alarm when ATEM Software Control's MIDI control is turned on

New 'pref' check reads an app setting on NA Ingest (defaults read) every
10 s; ATEM shows ATEM SW MIDI ON if midiEnabled is not 0.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
2026-10-11 09:52:33 -04:00
co-authored by Claude Opus 5.5
parent 0a4352bb92
commit b468b42889
3 changed files with 26 additions and 2 deletions
+4 -1
View File
@@ -171,7 +171,10 @@
] },
{ "id": "service", "label": "ALARMS", "pos": [3, 0], "kind": "service" },
{ "id": "atem", "label": "ATEM", "pos": [3, 1], "checks": [{ "type": "conn", "conn": "ATEM" }] },
{ "id": "atem", "label": "ATEM", "pos": [3, 1], "checks": [
{ "type": "conn", "conn": "ATEM" },
{ "type": "pref", "domain": "com.blackmagic-design.ATEM Software Control", "key": "midiEnabled", "want": "0", "msg": "ATEM SW MIDI ON" }
] },
{ "id": "obs", "label": "OBS", "pos": [3, 2], "checks": [{ "type": "conn", "conn": "OBS-Youtube", "service_only": true, "fix": "obs" }] },
{ "id": "resi", "label": "RESI", "pos": [3, 3], "checks": [
{ "type": "conn", "conn": "RESI_Decoder", "tag": "DECODER" },